SERVICES

Our scalable Tier III data center facilities are designed to match the requirements of the most demanding IT environments, and we provide both established companies and start-ups in Silicon Valley with safe and secure room to grow.

SPACE

POWER

CONNECTIVITY

COOLING

SPACE

We understand that there are many choices for companies requiring data center space, ranging from mission critical to lab space. However, not all IT loads are created equal, and our clients demand hybrid solutions. Our team will work with you to understand your exact requirements and only then will we craft the right solution for you. Our data centers are built around flexible configuration of standardized components, such as: same size UPS systems, generators, and CRAH units, down to the smallest circuits that we deploy (30A/208V=6kW). And all of our circuits have built-in branch circuit monitoring. This allows for common inventory parts, simplicity in design that results in lower operational costs for us, and greater savings for our clients. We can deploy a private suite utilizing these common components.

POWER

Receive up to 20 KW of usable data center power per cabinet (equivalent of four 208V-30A power circuits). Note: the redundant (B side) power circuits are not included in this power calculation.

IP-addressable power strips containing ampacity meters viewable at any time on your customer dashboard.

Backup generator systems in place in the event of local utility failure. System designed to automatically transition to stand-by diesel generator backup whenever an under-voltage condition persists

Power distributed from the UPS through K-rated transformers to local panel distribution panels and branched to computer cabinets.

CONNECTIVITY

Our colocation cabinet and cage solutions are backed by Element Critical’s 100% Up-time Service Level  Agreement (SLA), covering all key elements and service metrics like power, temperature, network availability and service credits. Note: The SLA relates to the use of products and services offered by Element Critical. Up-time commitments shall not apply during the initial two weeks after each installation or material alteration.

If Element Critical fails to meet the relevant up-time commitments set forth in the SLA, you may request a credit. Upon verification, we will credit your account as outlined in your SLA. You may request a copy of our 100% Data Center Uptime SLA at any time.

COOLING

Our mechanical data center engineers and operations staff are expert HVAC folks. In additional to keeping the core infrastructure running at optimal efficiency, they’re directly involved in solutions engineering and high-density deployments to 30 kW and beyond.

Our Service Level Agreements are designed to meet recommended ASHRAE temperature range requirements.

 